This Disposable Infusion Pump (also known as an Elastomeric Pain Relief Pump) is a premium medical consumable designed for safety, portability, and precise drug delivery. Powered by a high-elasticity, medical-grade silicone reservoir, the pump utilizes physical contraction pressure to maintain a constant flow of medication. Its core strengths lie in the Multi-rate Adjustment Valve and the PCA (Patient-Controlled Analgesia) Module, which allow clinicians to customize flow rates based on patient needs while empowering patients to self-administer additional doses during peak pain episodes via a manual button.
It is primarily used for postoperative analgesia (post-surgery pain relief), painless childbirth (labor analgesia), chronic pain management, and palliative care for late-stage cancer. It ensures a stable, micro-dose delivery of medication into the patient’s venous or epidural space for a duration ranging from 2 days to 1 week.
| Parameter | Details |
| Capacity Range | 60ml, 100ml, 150ml, 200ml, 275ml, 300ml up to 600ml (Customizable) |
| Duration of Use | 48 hours (2 days) to 168 hours (7 days) |
| Delivery Modes | Continuous Basal Infusion (CBI) / Multi-rate / Patient-Controlled Analgesia (PCA) |
| Flow Rate Range | 0.5ml/hr - 14ml/hr (Customizable flow settings available) |
| PCA Module | Bolus dose: 0.5ml; Lock-out time: 15 minutes |
| Primary Material | Medical-grade Silicone (Reservoir), DEHP-Free PVC (Tubing) |
| Color/Appearance | High-transparency shell, Blue/White adjustment knobs & buttons |
| Sterilization | Ethylene Oxide (EO) Sterilization, Non-pyrogenic |
Precise Multi-rate Control: The rotary valve design allows healthcare providers to switch between multiple flow rates on a single device, accommodating patients of different body weights.
Safety Lock-out Mechanism: The 15-minute PCA lock-out time is a scientifically validated interval that effectively prevents drug overdose caused by repetitive pressing.
High Biocompatibility: The reservoir is made of premium medical silicone, ensuring no physical or chemical changes to the medication during extended infusion periods of up to one week.
Passive Power Source: No batteries or external electricity required. Its lightweight design supports early patient mobilization and accelerates postoperative recovery.
Integrated Gas Filtration: The specialized silicone reservoir and infusion set are designed to filter and trap air, preventing air bubbles from entering the patient's system.
Q: What should I do if air is accidentally injected into the elastomeric reservoir during the filling process?
A: There is no need for concern. The elastomeric reservoir system is designed to filter gases. The reservoir will automatically filter and trap micro-air bubbles, preventing them from entering the delivery tubing to ensure patient safety.
Q: What happens if a patient presses the PCA button twice in a row?
A: The pump has a built-in safety lock. Within 15 minutes after the first press, any subsequent presses will not trigger a bolus dose.
Q: Is this pump reusable?
A: No. This is a single-use sterile medical device. Re-sterilization and reuse are strictly prohibited.
Q: Can the flow rate be customized for specific requirements?
A: Yes. We offer customization for both the continuous basal flow rate and the PCA bolus volume to meet specific clinical needs.